Is rooftop solar safe? Fire risk, rapid shutdown and insurance in Thailand, 2026
Rooftop solar built with certified parts and installed to standard is not inherently dangerous, but loose or poor DC connections can arc and start fires, and DC voltage can remain on the roof even with the main breaker off [1]. Since 30 October 2026 panels sold in Thailand must meet TIS 61730 Part 2, which includes fire-spread tests, and the Engineering Institute of Thailand's 2022 standard calls for rapid shutdown that brings array voltage to no more than 80 V within 30 seconds [2][3][4]. PEA (the Provincial Electricity Authority, กฟภ., which supplies the other 74 provinces) warns that a non-standard installation may affect your insurance cover [5].
Key facts
- The main fire causes in solar systems are DC arcs at loose, corroded or badly made connections, failed bypass diodes and poorly placed inverters [1].
- From 30 October 2026, crystalline silicon panels must meet TIS 61730 Part 2-2567, which tests heat resistance, insulation, leakage, fire spread and mechanical strength; violations carry fines of up to 2 Mn THB [2][3].
- The TISI board approved five more solar products as controlled in June 2026: PV cable, lithium storage batteries, PV fuses, inverters and DC circuit breakers [6].
- In August 2026 it added connectors and switchgear assemblies, expected to be enforced in December 2026 [7].
- In May 2026 the OCPB investigated an installation that used aluminium instead of copper cable and converted a three-phase supply to single-phase, causing melted parts and losses of more than 500,000 THB [8].
- A detailed system check costs about 1,500 to 3,000 THB, according to an installer's estimates [9].
kWp is the peak capacity of the solar panels; kW is the size of the inverter or the system.
What checks keep a system safe, and what do they cost?
| Check | How often | Cost | What it catches |
|---|---|---|---|
| Look at the panels, cables and inverter from the ground | Monthly | Nothing | Loose cables, damage, birds' nests, scorch marks |
| Read the app's alarm log | Weekly | Nothing | Insulation, arc and overtemperature alarms |
| Keep the inverter and battery area clear and ventilated | Always | Nothing | Heat build-up near flammable materials [1] |
| Professional check: connector tightness, cable condition, thermal scan for hot spots | Every one to two years, or after storms | About 1,500 to 3,000 THB [9] | Arcing connections, failing diodes, hot spots [1] |
| Cleaning | When output drops | About 2,500 to 4,000 THB a visit [9] | Dirt that causes hot spots on part of a panel [1] |
As of 17 November 2026. Check prices are installer estimates; frequency is our suggestion based on Howden's maintenance checklist [1].
What should a safe installation include?
- Certified parts: panels with a TIS 61730 Part 2 licence, and inverters, cables, fuses, DC breakers and batteries that meet the standards made mandatory or being made mandatory [2][6][7]. For connectors and cables, Howden points to IEC 62852 [1].
- Matched connectors: DC connectors of the same make and type on both sides of each joint, crimped with the right tool, because loose or badly made joints can arc [1].
- Rapid shutdown: microinverters, optimisers or a shutdown device that meets the EIT 2022 limit of 80 V within 30 seconds [4].
- A DC isolator and labels: a clearly labelled DC isolator near the inverter, and a sign at the switchboard that the building has solar.
- Inverter placement: ventilated, out of direct sun, away from flammable materials and with the maker's clearances [1].
- Copper cable sized for the load, not aluminium substitutes [8].
- A licensed engineer's signature on the single line diagram [10].
What should you do in an emergency?
- If there is smoke or fire, leave the building and call the fire service on 199.
- Tell firefighters the building has solar, and where the inverter and DC isolator are; panels keep producing DC voltage in daylight [1].
- Switch off the AC breaker and the DC isolator only if you can reach them safely.
- Do not touch panels, cables or a melted connector, and do not spray water on live equipment yourself.
- After the event, keep the system off until a licensed electrician has inspected it, and photograph the damage for the installer and the insurer.
What about warranties and insurance?
- Insurance: PEA warns that a non-standard installation may affect insurance coverage conditions [5]. Tell your home insurer about the system, and keep the engineer-signed diagram, equipment certificates and the utility's connection approval.
- Installation warranty: connector and cabling faults are workmanship; claim them from the installer within the installation warranty, usually 1 to 3 years in the packages we read [11][12].
- Consumer complaints: if the installer refuses responsibility, the OCPB can gather the facts and take action on consumers' behalf; it had received 156 solar complaints since 2024 [13].
Read next: installer rankings, how we score, string, micro or optimiser, how to check an installer, roofs and leaks, home batteries and low production.
Frequently asked questions
Can solar panels catch fire?
They can, but the usual cause is the installation rather than the panel. Loose, corroded or badly made DC connections can arc and ignite nearby material, and failed bypass diodes or poorly placed inverters add risk. Certified parts, matched connectors, correct cable and periodic checks of connectors and hot spots keep the risk low.
Is rapid shutdown required in Thailand?
The Engineering Institute of Thailand's 2022 rooftop PV standard calls for rapid shutdown that brings voltage inside the array boundary to no more than 80 V within 30 seconds. Microinverters, panel optimisers or a separate shutdown device can meet it. Ask the installer which one the quote includes, and get it in writing.
Does home insurance cover solar panels?
Check your policy. PEA warns that a non-standard installation may affect insurance coverage conditions, so tell your insurer about the system and keep the engineer-signed diagram, equipment certificates and the utility's connection approval. Ask whether the panels, inverter and battery are covered for fire, storm and lightning damage.
Is it safe to have a battery at home?
A lithium battery installed to the maker's instructions, in a ventilated place away from flammable materials, is a managed risk. The TISI board has approved lithium storage batteries as a controlled product, so ask for a battery that meets TIS 63056 once it is enforced, and keep the battery out of bedrooms and escape routes.
What should I check on my solar system each month?
From the ground, look for loose or hanging cables, scorch marks, damaged panels and nests. In the app, read the alarm log for insulation, arc or overtemperature alarms. Keep the inverter area clear. If you see heat, melting or a burning smell, switch off as the manual describes and call a licensed electrician.
Who is responsible if a bad installation causes damage?
The installer is responsible for its workmanship under the contract and the installation warranty. Put your complaint in writing with photos, and if the installer refuses, contact the OCPB, which investigated a case in 2026 involving aluminium cable and melted parts. Paying by credit card can also give you a dispute route.
Sources
- Howden Thailand: solar rooftop fire risks, DC arc faults, bypass diode failure, inverter placement, residual DC voltage, certified components and maintenance. https://www.howdengroup.com/th-en/solar-rooftop-fire-risk Published 24 June 2026, read 17 November 2026.
- Thai PBS Policy Watch: crystalline silicon panels must meet TIS 61730 Part 2-2567 from 30 October 2026. https://policywatch.thaipbs.or.th/article/economy-311 Read 17 November 2026.
- Post Today: the panel standard tests heat resistance, insulation, leakage, fire spread and mechanical strength; fines of up to 2 Mn THB. https://www.posttoday.com/smart-city/751056 Published 28 October 2026, read 17 November 2026.
- KMUTT: rapid shutdown devices under the EIT 2022 rooftop PV standard, no more than 80 V within 30 seconds inside the array boundary. https://kirim.kmutt.ac.th/converis/portal/detail/Publication/1505021298?lang=en_GB Read 17 November 2026.
- Amarin TV, PEA press release: non-standard solar rooftop installation may affect insurance coverage conditions. https://www.amarintv.com/prnews/news/551297 Published 9 July 2026, read 17 November 2026.
- Daily News: the TISI board approves PV cable, lithium storage batteries, PV fuses, inverters and DC circuit breakers as controlled products, meeting of 23 June 2026. https://www.dailynews.co.th/news/5987773/ Read 17 November 2026.
- Thai Post: the TISI board approves connectors and switchgear assemblies as controlled products, expected to be enforced in December 2026. https://www.thaipost.net/economy-news/1059213/ Published 28 August 2026, read 17 November 2026.
- Thai PBS: the OCPB investigates a substandard solar installation with aluminium cable and a three-phase to single-phase conversion, losses of more than 500,000 THB. https://www.thaipbs.or.th/news/content/505886 Published 14 May 2026, read 17 November 2026.
- Thansettakij: one million rooftop solar households, cleaning and maintenance costs after installation. https://www.thansettakij.com/economy/670304 Published 30 September 2026, read 17 November 2026.
- Thansettakij: selling power to MEA in 2026, equipment, documents and engineer licence levels. https://www.thansettakij.com/general-news/663189 Read 13 November 2026.
- HomePro: Home Solar 3 kW 1-phase Normal, 1-year installation warranty. https://www.homepro.co.th/p/1254037 Read 13 November 2026.
- HomePro: ENERGY LIB P1 ALL IN ONE 8 kW set, 3-year installation warranty. https://www.homepro.co.th/p/1279912 Read 17 November 2026.
- The Standard: the OCPB has received 156 solar complaints since 2024. https://thestandard.co/?p=1209170 Read 17 November 2026.